How to make a gas booster pump into a gas booster system? The technical requirements for the gas booster system are as follows

    How to make a gas booster pump into a gas booster system? The technical requirements for the gas booster system are as follows:

    1、 The core component is the Taizhou Feentor gas booster pump ZTD60 single-stage double acting booster pump. The on-site pressure is 300 bar, and the valve W27.8 thread specification is subjected to gas seal testing. We need to develop an integrated control system with a customer inlet pressure of 10Mpa and thread size of external PT1/4. We need to connect a section of high-pressure hose to the gas pressurization system for docking, and preliminarily reserve 5M for the hose.

    2、 High pressure requires the configuration of a 3-meter high-pressure stainless steel pipeline, and the equipment outlet should be connected to the on-site external thread PT1/2 to ensure that the metal pipe is a stainless steel pipe with an outer diameter of φ 6 and a pressure resistance value of 100Mpa. It is necessary to use reverse screw nuts for sealing, and it is not allowed to use raw material belt machine anaerobic adhesive for sealing.

    3、 The gas pressurization system enclosure adopts a stainless steel piano style operating table with dimensions of 800 * 600 * 1200 (length, width, and height mm), which needs to conform to ergonomics. The bottom has universal wheels for easy movement, and the interior of the enclosure needs to be equipped with sound insulation strips for sound insulation and sealing.

    4、 The system layout requires the configuration of a driver pressure gauge with a range dial diameter of 60mm (0-10bar), an intake pressure gauge dial diameter of 100mm (0-25Mpa), a high-pressure output pressure gauge with an axial edge of 100mm (0-60mpa), and a pressure gauge accuracy not lower than level 1.6. The high-pressure switches consist of three high-pressure needle valves (intake needle valve, high-pressure needle valve, unloading needle valve). The ball valve is a driven ball valve (requires a silencer). The high-pressure pneumatic booster pump needs to be equipped with a binary oil-water separator. The pressure regulating valve needs to use SMC or Feentor manufacturer's designated brand, and the installation panel needs to have labeling reminders.