What are the operating procedures and experimental processes for gas booster pumps?

    Operating procedures for gas booster pump

    1. Carefully inspect whether the gas booster pump, pressure testing pipeline, pressure gauge, valve, and pressure vessel are safe and reliable

    During the pressure test, the accessories related to the gas booster pump must comply with the certification requirements, and the operating pressure must be used according to the requirements, not exceeding the required pressure of the product

    3. The pipeline connecting the equipment must have a pressure greater than the rated pressure of the gas boosting product by 4Mpa, and the pressure resistance value should be selected for pipelines with a pressure greater than 1.5-2 times the pressure

    When the gas pressurization system is in operation, if any leakage is found in the pressurized container, it is not allowed to strike or weld under pressure. If welding must be repaired, the pressure should be reduced to zero before proceeding

    5. When conducting pump pressure experiments in winter, anti freezing measures must be taken, and the water in the compressed container and pneumatic two-piece water cup must be drained regularly. The textile freeze damaged gas booster pump and accessories

    6. During the operation of the gas booster pump, clear safety signs must be hung around the experimental site stating "No unauthorized personnel allowed to enter the high-pressure air pump"

    After the pump pressure work is completed, release the pressure inside the pressurized container and turn off the drive air source switch

    8. Clean and tidy up the usage site, arrange objects neatly, and maintain equipment before leaving

    Test process of gas booster pump

    1. Check whether the driving gas and control gas pipelines are connected properly to the tested product;

    2. Adjust the pressure of the manual pressure regulating valve and the high-pressure reducing valve to zero;

    3. Close all valves; Turn on the booster pump drive air switch, adjust the drive air source pressure, and ensure that the equipment and drive air source pressure remain constant

    In a 5-fold proportional relationship, after the pressure is balanced, the booster pump automatically stops working. During this period, if the pressure in the gas storage tank is lower than the operating pressure or disproportionate to the gas source pressure, the booster pump automatically replenishes the pressure to achieve automatic pressure maintenance;

    When the equipment is not in use, simply turn off the drive air source switch, and the booster pump will no longer work;

    6. Any disassembly of components must be carried out without pressure;