Maintenance content and requirements for pneumatic gas booster pump

    Maintenance content and requirements for pneumatic gas booster pump

    One appearance

    1.1 Regularly wipe the surface of equipment, pressure gauges, gas storage tanks, valves, etc. to maintain cleanliness and absence of impurities

    1.2 Check if the equipment screws and nuts are complete

    II Equipment main components

    2.1 Check all fasteners of the equipment for looseness and adjust them according to the situation

    2.2 Check the sealing of compressed air storage tanks, valves, and pressure gauges to ensure no leakage occurs

    2.3 Disassemble the output and input pipelines according to the situation, and be sure to disassemble them without pressure. In case of sudden accidents, please contact the manufacturer as soon as possible. If replacement parts are needed, please use the original manufacturer's accessories. Our company cannot guarantee any other options, and any losses incurred as a result shall be borne by the user

    III Regular drainage of gas booster pump with gas storage tank

    3.1 Pneumatic two-piece water pump should be drained regularly, oil cup should be refilled regularly (VG32 turbine oil, etc.), and the pressure vessel should have a drain valve at the bottom for regular drainage

    4 On site environment and gas source

    4.1 The site must be clean and free of dust, and the gas source must be clean and dry, strictly used according to the manufacturer's requirements

    5、 Temperature requirements

    5.1 Conventional booster pumps can withstand working temperatures of -20~80 ℃. If the temperature exceeds this range, the pump must be shut down. Only when the temperature is normal can it be turned on. High temperature resistant pumps operate according to the specified temperature

    Pneumatic gas booster pump